Part Number Hot Search : 
75M000 INTEGRA SEL4928A X84C1 M6270X P136000 C79L08BP TSL1112S
Product Description
Full Text Search
 

To Download PD5002P-17 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  features low forward volage drop high current capability high reliability high surge current capability mechanical case: ofc heat sink encap:epoxy sealed rated ul94v-0 weight: 7.05gram p black n brown dimensions in inches and (millimeters) maximum ratings and electrical characteristics rating at 25 unless otherwise specified. single phase,half wave,60hz,resistive or inductive load . for capacitive load,deraate current by 20% maximum peak repetitive reverse voltage @irrm=10ua v maximum rms voltage v maximum dc blocking voltage t a =25 v peak forward surage current 8.3ms single half sine-wave superimposed on rated load (jedec method) a maximum inst. forward voltage drop, i f at 100amp v operating temperature range storage temperature range rev. 7, 16-mar-2017 characteristics maximum average forward current i o @t c =150 60h z ,resistive or inductive load marking glass passivated auto rectifiers 400 600 v b i (av) a ua 600 420 symbol 10 5002 200 pd5002p(n) 1.1 140 200 50 pd5002p(n) thru pd5006p(n) 400 600 280 5004 5006 v rrm v rms reverse voltage -200 to 600volts forward current -50 amperes unit pd5004p(n) pd5006p(n) ring color t j t stg i fsm v f i r 500 -40to+200 -40to+200 maximum dc reverse current (vb)@t j =25 at rated dc bolcking voltage (vb)@tj=175 press-fit .500(12.70) .506(12.85) .409(10.4) .417(10.6) .193(4.9) .201(5.1) .360(9.0) .370(9.4) 1.063(27.0) 1.181(30.0) .042(10.7) .044(11.1) .049(1.25) .053(1.35)
the cruve graph is for reference only, can't be the basis for judgment( ?)! rev. 7, 16-mar-2017 rating and characteristic curves pd5002p(n) thru pd5006p(n) fig.1-forward current derating curve average forward rectified current , amperes case temperature, 50 100 0 150 10 50 40 30 20 60 80 70 200 250 0 60hz resistive or inductive load fig.3 -typical instantaneous forward characteristics instantanceous forward current, amperes instantaneous forward voltagevolts 1000 1 1.4 1.2 1.0 0.8 0.6 0.4 0.2 100 10 1.6 t j =25 pulse width=300s 1%duty cycle fig.4-typical reverse characteristics percent of rated peak reverse voltage, % instantanceous reverse current, micramperes t j =25 t j =175 1000 0.01 0 20 40 60 80 100 0.1 1 10 100 fig.2-maximum non-retetitive peak forward surge current number of cycles at 60h z peak forward surge current amperes 500 400 0 100 10 1 300 200 100 600 pulse width 8.3ms single half-wave (jedec method)
legal disclaimer notice all specifications and data are subject to be changed without notice to improve reliability function or design or other reasons. hy makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the co- tinuing production of any product. to the maximum extent permitted by applicable law, hy disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,consequential or incidental d- amages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merch- antability. statements regarding the suitability of products for certain types of applications are based on hy?s knowledge of typical require- ments that are often placed on hy products in generic applications. such statements are not binding statements about the suitabi- lity of products for a particular application. it is the customer?s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application.parameters provided in datasheets and specific- ations may vary in different applications and performance may vary over time. all operating parameters, including typical paramet- ers, must be validated for each customer application by the customer?s technical experts. product specifications do not expand or otherwise modify hy?s terms and conditions of purchase, including but not limited to the warranty expressed therein. except as expressly indicated in writing, hy products are not designed for use in medical, life-saving, or life-sustaining applicati- ons or for any other applications in which the failure of the hy product could result in personal injury or death. customers using or selling hy products not expressly indicated for use in such applications do so at their own risk.please contact authorized hy pers- onnel to obtain written terms and conditions regarding products designed for such applications. no license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of hy. product names and markings noted herein may be trademarks of their respective owners. ?????????? hy ???????????hy (i) ? ??????(ii) ???????(iii) ??? ???????? ????? hy ? hy ???????????? ???????????????? ????? ????????????? ??? hy ???? hy ???? ?hy ????? hy ??????? ?????? hy ????????hy ?? ? ? hy ??????????????????? ??? rev. 2, 16-mar-2017 disclaimer


▲Up To Search▲   

 
Price & Availability of PD5002P-17

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X